Batteries follow solar. Same rule: VoltView reads the inverter or battery portal. We do not dispatch the battery in v1. A battery in VoltView is one storage system on one site, mapped to the same site and import MPAN as the solar it sits with (if any).

When this ships

After the solar connect-and-map path is live on at least one OEM. Do not promise battery data on a site until that path exists.

What you get

With solar and the import meter on the same site, VoltView can then show whether the battery charged from solar, from the grid, or covered a peak that would otherwise have been imported. “Covered a peak” means the battery discharged in the same settlement interval as the maximum demand — usually a half-hour. Those splits are derived. They need all three feeds (solar, battery, meter) on the same interval.

Connect

Same preference order as solar:
  1. OEM API token.
  2. Read-only portal user.
  3. Installer share.
  4. File export (not a live feed).
Hybrid inverters often expose PV and battery on the same portal. In that case one connection can populate both a solar system and a battery on the site. Still store them as two assets so the meter mapping stays explicit.

Map to the site

Ownership

Same test as solar. If a funder owns the battery, their portal is the one that matters. Many UK C&I PPA roofs have no storage. Do not create a battery asset because the customer is “interested in batteries.”

Supported after solar

No battery connector is in v1 until solar is shipping. The first targets are the portals we will already be in for PV: Residential products (for example Powerwall on a house) are not the C&I default. Add them only for a real site.

What we do not do yet

  • Charge, discharge, or change a backup reserve.
  • Tariff-based optimisation on the battery.
  • Flexibility / VPP enrolment.
  • Sizing or payback as a live control loop. Modelling stays in the account conversation, not in the asset API.

Checks after first pull

  1. Usable kWh matches the commissioning sheet.
  2. SOC stays in 0–100 and moves when charge/discharge power is non-zero.
  3. Interval energy is consistent with average power over the interval.
  4. If linked solar exists, battery charge in daylight is not treated as grid charge without looking at generation.